Nitrogen Convection Models
N70
New Super Nitrogen Reflow Technology
Feature
- Low price supply is realized through the high performance, high quality and localization for lead-free soldering
- Operation cost reduction can be realized with little N2 consumption
- Preheating and main heating zone can be changed and setup by configuring the multi heating zone
- Equipped with cooling system radiator type flux recovery function
- High precision oxygen concentration control is realized through automatic oxygen concentration control.
Specifications
|
Description |
N70-K82 |
N70-K102 |
N70-K103 |
N70-K122 |
|---|---|---|---|---|
|
Apparent power(kw) |
44kw |
49kw |
49kw |
57kw |
|
Average power consumption(kw) |
Approximate 10kw |
Approximate 13kw |
Approximate 13kw |
16kw |
|
Operating voltage(V) |
3Ø 380V 50/60Hz, 3Ø 220V 50/60Hz, |
|
||
|
Operating Current(A) |
64A(110A) |
75A(129A) |
75A(129A) |
88A(152A) |
|
Outline dimension (LxWxH) |
4422x1340x1450 |
4938x1340x1450 |
5633x1340x1450 |
5633x1340x1450 |
|
Weight (kg) |
2500 |
2800 |
3000 |
3000 |
|
Number of heating zones |
8 zone |
10 zone |
10 zone |
12 zone |
|
Heating Zone Length |
2200 |
2700 |
2700 |
3200 |
|
Number of cooling zone |
2 zone |
2 zone |
3 zone |
2 zone |
|
Cooling Method |
N2 atmosphere |
N2 atmosphere |
N2 atmosphere |
N2 atmosphere |
|
Flux treatment |
Cooling zone |
Cooling zone |
Entrance+ Cooling zone |
Cooling zone |
|
PCB Transfer Speed |
0.3-1.6m/min |
|||
|
PCB transfer direction |
Left to right, right to Left |
|||
|
Fixed Conveyor Rail |
Front Rail (Rear Rail) |
|||
|
PCB Dimension (mm) |
2”- 16” (18”, 20”, 22” option) / 50-410 (460, 500, 560 Option) |
|||
|
Conveyor belt height(mm) |
885-920 mm from floor (normally 900 mm) |
|||
|
Temperature meter |
16ch |
20ch |
20ch |
24ch |
|
Hot Air Speed |
Pre-heat & reflow Approximately 0.5-4.0m/sec |
|||
|
PCB drop detection |
Photo sensor |
|||
|
PCB stop detection |
Photo Sensor |
|||
|
Auto stop |
Stops after No-load for 20-60 minutes since the system turns off |
|||
|
Oxygen connection control |
O2 Analyzer |
02 Analyzer |
02 Analyzer |
02 Analyzer |
|
Nitrogen concentration indication |
O2 Controller |
O2 Controller |
O2 Controller |
O2 Controller |
|
Nitrogen consumption |
12-15m²/h (Based on 500ppm) |
|
||
|
Alarm monitor |
PC monitor indication/ Emergency stop/ conveyor problem/ Cover opened/ Board drop alarm/ board stop alarm/ Abnormal temperature alarm/ Thermal Alarm/ abnormal % ppm/ N2 presure |
|||
|
Others |
PC, UPS, Anti-warp conveyor or Mesh belt(option) |
|||
Specification may change without notice
N2 Generator Fixing Type
Feature
- Easy Maintenance, Application of high durability solenoid valves allows easy maintenance.
- Simple, It is possible to supply high purity N2 Gas only by turning on the power supply
- It is possible to supply high purity N2 gas with low dew point stably
Specifications
|
Model |
Capacity Nm³/hr (99.99%) |
Discharge pressure |
Air compressor (kw) |
Weight (kg) |
Dimension DxWxHmm |
|---|---|---|---|---|---|
|
TP-N30R-99 |
30 |
0.5 |
22 |
1520 |
1400x1520x2100 |
|
TP-N40R-99 |
40 |
30 |
1830 |
1450x1600x2300 |
|
|
TP-N50R-99 |
50 |
2340 |
1500x1750x2400 |
||
|
TP-N60R-99 |
60 |
37 |
2610 |
1650x1850x2600 |
|
|
TP-N80R-99 |
80 |
55 |
3100 |
1800x2050x2800 |
|
|
TP-N100R-99 |
100 |
75 |
3200 |
1850x1700x3000 |
|
|
TP-N120R-99 |
120 |
90 |
3400 |
1950x1800x3200 |
N2 Generator Moving Type
Feature
- Compact N2 Built in N2 generator developed by TSM with our own technology, it alows the N2 reflow to be used easily at any location
- Available 3 models, 10Nm³, 12Nm³, 15Nm³
- Part per Million (ppm) according to air pressure when applying a built in PSA
Specifications
|
PSA Inlet air pressure |
O2 control range inside the reflow |
|---|---|
|
7.5 (kg/cm³) |
~500ppm |
|
6.5 (kg/cm³) |
700ppm ~ |
|
5.5 (kg/cm³) |
1000ppm ~ |