Nitrogen Convection Models

N70

New Super Nitrogen Reflow Technology

Feature

  • Low price supply is realized through the high performance, high quality and localization for lead-free soldering
  • Operation cost reduction can be realized with little N2 consumption
  • Preheating and main heating zone can be changed and setup by configuring the multi heating zone
  • Equipped with cooling system radiator type flux recovery function
  • High precision oxygen concentration control is realized through automatic oxygen concentration control.

Specifications

Description

N70-K82

N70-K102

N70-K103

N70-K122

Apparent power(kw)

44kw

49kw

49kw

57kw

Average power consumption(kw)

Approximate 10kw

Approximate 13kw

Approximate 13kw

16kw

Operating voltage(V)

3Ø 380V 50/60Hz, 3Ø 220V 50/60Hz,

 

Operating Current(A)

64A(110A)

75A(129A)

75A(129A)

88A(152A)

Outline dimension (LxWxH)

4422x1340x1450

4938x1340x1450

5633x1340x1450

5633x1340x1450

Weight (kg)

2500

2800

3000

3000

Number of heating zones

8 zone

10 zone

10 zone

12 zone

Heating Zone Length

2200

2700

2700

3200

Number of cooling zone

2 zone

2 zone

3 zone

2 zone

Cooling Method

N2 atmosphere
cooling
Chiller( option)

N2 atmosphere
cooling
Chiller( option)

N2 atmosphere
cooling
Chiller( option)

N2 atmosphere
cooling
Chiller( option)

Flux treatment

Cooling zone

Cooling zone

Entrance+ Cooling zone

Cooling zone

PCB Transfer Speed

0.3-1.6m/min

PCB transfer direction

Left to right, right to Left

Fixed Conveyor Rail

Front Rail (Rear Rail)

PCB Dimension (mm)

2”- 16” (18”, 20”, 22” option) / 50-410 (460, 500, 560 Option)

Conveyor belt height(mm)

885-920 mm from floor (normally 900 mm)

Temperature meter

16ch

20ch

20ch

24ch

Hot Air Speed

Pre-heat & reflow Approximately  0.5-4.0m/sec

PCB drop detection

Photo sensor

PCB stop detection

Photo Sensor

Auto stop

Stops after No-load for 20-60 minutes since the system turns off

Oxygen connection control

O2 Analyzer

02 Analyzer

02 Analyzer

02 Analyzer

Nitrogen concentration indication

O2 Controller

O2 Controller

O2 Controller

O2 Controller

Nitrogen consumption

12-15m²/h (Based on 500ppm)

 

Alarm monitor

PC monitor indication/ Emergency stop/ conveyor problem/ Cover opened/ Board drop alarm/ board stop alarm/ Abnormal temperature alarm/ Thermal Alarm/ abnormal % ppm/ N2 presure

Others

PC, UPS, Anti-warp conveyor or Mesh belt(option)

Specification may change without notice


N2 Generator Fixing Type

Feature

  • Easy Maintenance, Application of high durability solenoid valves allows easy maintenance.
  • Simple, It is possible to supply high purity N2 Gas only by turning on the power supply
  • It is possible to supply high purity N2 gas with low dew point stably

Specifications

Model

Capacity Nm³/hr (99.99%)

Discharge pressure

Air compressor (kw)

Weight (kg)

Dimension DxWxHmm

TP-N30R-99

30

0.5

22

1520

1400x1520x2100

TP-N40R-99

40

30

1830

1450x1600x2300

TP-N50R-99

50

2340

1500x1750x2400

TP-N60R-99

60

37

2610

1650x1850x2600

TP-N80R-99

80

55

3100

1800x2050x2800

TP-N100R-99

100

75

3200

1850x1700x3000

TP-N120R-99

120

90

3400

1950x1800x3200


N2 Generator Moving Type

Feature

  • Compact N2 Built in N2 generator developed by TSM with our own technology, it alows the N2 reflow to be used easily at any location
  • Available 3 models, 10Nm³, 12Nm³, 15Nm³
  • Part per Million (ppm) according to air pressure when applying a built in PSA

Specifications

PSA Inlet air pressure

O2 control range inside the reflow

7.5 (kg/cm³)

~500ppm

6.5 (kg/cm³)

700ppm ~

5.5 (kg/cm³)

1000ppm ~